Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Clin Microbiol ; 59(3)2021 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-33298613

RESUMEN

With the approach of respiratory virus season in the Northern Hemisphere, clinical microbiology and public health laboratories will need rapid diagnostic assays to distinguish severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from influenza virus and respiratory syncytial virus (RSV) infections for diagnosis and surveillance. In this study, the clinical performance of the Xpert Xpress SARS-CoV-2/Flu/RSV test (Cepheid, Sunnyvale, CA, USA) for nasopharyngeal swab specimens was evaluated in four centers: Johns Hopkins Medical Microbiology Laboratory, Northwell Health Laboratories, NYC Public Health Laboratory, and Los Angeles County/University of Southern California (LAC+USC) Medical Center. A total of 319 nasopharyngeal swab specimens, positive for SARS-CoV-2 (n = 75), influenza A virus (n = 65), influenza B virus (n = 50), or RSV (n = 38) or negative (n = 91) by the standard-of-care nucleic acid amplification tests at each site, were tested using the Cepheid panel test. The overall positive percent agreement for the SARS-CoV-2 target was 98.7% (n = 74/75), and the negative agreement was 100% (n = 91), with all other analytes showing 100% total agreement (n = 153). Standard-of-care tests to which the Cepheid panel was compared included the Cepheid Xpert Xpress SARS-CoV-2, Cepheid Xpert Xpress Flu/RSV, GenMark ePlex respiratory panel, BioFire respiratory panel 2.1 and v1.7, DiaSorin Simplexa COVID-19 Direct, and Hologic Panther Fusion SARS-CoV-2 assays. The Xpert Xpress SARS-CoV-2/Flu/RSV test showed high sensitivity and accuracy for all analytes included in the test. This test will provide a valuable clinical diagnostic and public health solution for detecting and differentiating SARS-CoV-2, influenza A and B virus, and RSV infections during the current respiratory virus season.


Asunto(s)
COVID-19/diagnóstico , Gripe Humana/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Humanos , Nasofaringe , SARS-CoV-2 , Sensibilidad y Especificidad
2.
Pediatr Infect Dis J ; 35(8): 894-900, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27164464

RESUMEN

BACKGROUND: Sexually transmitted infections (STIs) in pregnancy such as Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) may lead to adverse infant outcomes. METHODS: Individual urine specimens from HIV-infected pregnant women diagnosed with HIV during labor were collected at the time of infant birth and tested by polymerase chain reaction for CT and NG. Infant HIV infection was determined at 3 months with morbidity/mortality assessed through 6 months. RESULTS: Of 1373 maternal urine samples, 277 (20.2%) were positive for CT and/or NG; 249 (18.1%) for CT, 63 (4.6%) for NG and 35 (2.5%) for both CT and NG. HIV infection was diagnosed in 117 (8.5%) infants. Highest rates of adverse outcomes (sepsis, pneumonia, congenital syphilis, septic arthritis, conjunctivitis, low birth weight, preterm delivery and death) were noted in infants of women with CT and NG (23/35, 65.7%) compared with NG (16/28, 57.1%), CT (84/214, 39.3%) and no STI (405/1096, 37%, P = 0.001). Death (11.4% vs. 3%, P = 0.02), low birth weight (42.9% vs. 16.9%, P = 0.001) and preterm delivery (28.6% vs. 10.2%, P = 0.008) were higher among infants of CT and NG-coinfected women. Infants who had any adverse outcome and were born to women with CT and/or NG were 3.5 times more likely to be HIV infected after controlling for maternal syphilis (odds ratio: 3.5, 95% confidence interval: 1.4-8.3). By adjusted multivariate logistic regression, infants born to mothers with any CT and/or NG were 1.35 times more likely to have an adverse outcome (odds ratio, 1.35; 95% confidence interval, 1.03-1.76). CONCLUSIONS: STIs in HIV-infected pregnant women are associated with adverse outcomes in HIV-exposed infected and uninfected infants.


Asunto(s)
Infecciones por Chlamydia/epidemiología , Gonorrea/epidemiología , Infecciones por VIH/epidemiología , Transmisión Vertical de Enfermedad Infecciosa/estadística & datos numéricos , Complicaciones Infecciosas del Embarazo/epidemiología , Infecciones por Chlamydia/complicaciones , Chlamydia trachomatis , Estudios de Cohortes , Femenino , Gonorrea/complicaciones , Infecciones por VIH/complicaciones , Humanos , Recién Nacido , Neisseria gonorrhoeae , Embarazo , Ensayos Clínicos Controlados Aleatorios como Asunto , Orina/microbiología
3.
Sex Transm Dis ; 42(10): 554-65, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26372927

RESUMEN

BACKGROUND: Sexually transmitted infections (STIs) such as Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) can lead to adverse pregnancy and neonatal outcomes. The prevalence of STIs and its association with HIV mother-to-child transmission (MTCT) were evaluated in a substudy analysis from a randomized, multicenter clinical trial. METHODOLOGY: Urine samples from HIV-infected pregnant women collected at the time of labor and delivery were tested using polymerase chain reaction testing for the detection of CT and NG (Xpert CT/NG; Cepheid, Sunnyvale, CA). Infant HIV infection was determined by HIV DNA polymerase chain reaction at 3 months. RESULTS: Of the 1373 urine specimens, 249 (18.1%) were positive for CT and 63 (4.6%) for NG; 35 (2.5%) had both CT and NG detected. Among 117 cases of HIV MTCT (8.5% transmission), the lowest transmission rate occurred among infants born to CT- and NG-uninfected mothers (8.1%) as compared with those infected with only CT (10.7%) and both CT and NG (14.3%; P = 0.04). Infants born to CT-infected mothers had almost a 1.5-fold increased risk for HIV acquisition (odds ratio, 1.47; 95% confidence interval, 0.9-2.3; P = 0.09). CONCLUSIONS: This cohort of HIV-infected pregnant women is at high risk for infection with CT and NG. Analysis suggests that STIs may predispose to an increased HIV MTCT risk in this high-risk cohort of HIV-infected women.


Asunto(s)
Infecciones por Chlamydia/transmisión , Gonorrea/transmisión , Seropositividad para VIH/complicaciones , Transmisión Vertical de Enfermedad Infecciosa/prevención & control , Madres , Profilaxis Posexposición , Complicaciones Infecciosas del Embarazo/prevención & control , Mujeres Embarazadas , Adulto , Argentina/epidemiología , Brasil/epidemiología , Infecciones por Chlamydia/inmunología , Infecciones por Chlamydia/prevención & control , Femenino , Gonorrea/inmunología , Gonorrea/prevención & control , Seropositividad para VIH/inmunología , Seropositividad para VIH/transmisión , Humanos , Lactante , Embarazo , Prevalencia , Factores de Riesgo , Sudáfrica/epidemiología , Estados Unidos/epidemiología
4.
J Clin Microbiol ; 51(11): 3780-7, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24006011

RESUMEN

Detecting colonization of patients with carbapenemase-producing bacteria can be difficult. This study compared the sensitivity and specificity of a PCR-based method (Xpert MDRO) for detecting blaKPC, blaNDM, and blaVIM carbapenem resistance genes using GeneXpert cartridges to the results of culture with and without a broth enrichment step on 328 rectal, perirectal, and stool samples. The culture method included direct inoculation of a MacConkey agar plate on which a 10-µg meropenem disk was placed and plating on MacConkey agar after overnight enrichment of the sample in MacConkey broth containing 1 µg/ml of meropenem. Forty-three (13.1%) samples were positive by PCR for blaKPC and 11 (3.4%) were positive for blaVIM; none were positive for blaNDM. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PCR assay for blaKPC were 100%, 99.0%, 93.0%, and 100%, respectively, compared to broth enrichment culture and sequencing of target genes. The sensitivity, specificity, PPV, and NPV of the assay for blaVIM were 100%, 99.4%, 81.8%, and 100%, respectively. Since none of the clinical samples contained organisms with blaNDM, 66 contrived stool samples were prepared at various dilutions using three Klebsiella pneumoniae isolates containing blaNDM. The PCR assay showed 100% positivity at dilutions from 300 to 1,800 CFU/ml and 93.3% at 150 CFU/ml. The Xpert MDRO PCR assay required 2 min of hands-on time and 47 min to complete. Rapid identification of patients colonized with carbapenemase-producing organisms using multiplex PCR may help hospitals to improve infection control activities.


Asunto(s)
Proteínas Bacterianas/genética , Portador Sano/diagnóstico , Bacterias Gramnegativas/enzimología , Bacterias Gramnegativas/aislamiento & purificación , Infecciones por Bacterias Gramnegativas/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena de la Polimerasa/métodos , beta-Lactamasas/genética , Proteínas Bacterianas/metabolismo , Técnicas Bacteriológicas/métodos , Portador Sano/microbiología , Heces/microbiología , Bacterias Gramnegativas/genética , Infecciones por Bacterias Gramnegativas/microbiología , Humanos , Perineo/microbiología , Recto/microbiología , Sensibilidad y Especificidad , beta-Lactamasas/metabolismo
5.
Expert Opin Med Diagn ; 3(1): 91-7, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23495966

RESUMEN

BACKGROUND: Few clinical scenarios are as diagnostically demanding as the workup of acute meningitis in the emergency room setting. In humans, most cases of meningitis are due to enteroviral infection, which usually resolves with supportive care and does not generally require hospitalization. The difficulty in evaluating meningitis is often related to its nonspecific presentation; rapid identification of the underlying etiologic agent is critical to selection of the most appropriate course of therapy. OBJECTIVE: To develop a rapid, automated polymerase chain reaction-based test for enteroviral meningitis that can be run on demand, and to make the test easy enough to operate that most hospital laboratories can offer it on an immediate basis in order to provide maximum medical impact. METHODS: A sensitive and specific test on the GeneXpert was developed for detection of enteroviral RNA in cerebrospinal fluid. The automated test was carried out in a disposable GeneXpert cartridge, which conducts the steps of nucleic acid purification, amplification and detection of enteroviral genomic RNA in ∼ 2 h. Preclinical and clinical studies showed sensitivities of 97.1 and 98%, respectively, and specificities of 100 and 97.1%, respectively. In February 2006, the test received FDA clearance as an aid in the diagnosis of viral meningitis. CONCLUSIONS: Rapid and accurate molecular diagnostic testing for enterovirus infection provides clinicians with information they need to make the best patient decisions in managing patients with meningitis. The GeneXpert enterovirus assay features on-demand availability and a level of simplicity that allows nearly any hospital laboratory to offer a sophisticated test that was once the exclusive domain of reference laboratories.

6.
J Clin Microbiol ; 45(4): 1081-6, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17251395

RESUMEN

The GeneXpert Dx system (Cepheid, Sunnyvale, CA) is a fully integrated and automated nucleic acid sample preparation, amplification, and real-time detection system. It consists of an instrument, a personal computer, and disposable fluidic cartridges. The analytical sensitivity and specificity of the GeneXpert enterovirus assay (GXEA) were determined with a panel of 63 different enterovirus serotypes and 24 other microorganisms, respectively. The potential for blood, hemoglobin, white blood cells, and excess protein to interfere with the assay was also assessed. The performance parameters of the GXEA were determined at three sites with 102 cerebrospinal fluid (CSF) samples obtained from patients with suspected meningitis. All samples were tested for enterovirus RNA with locally developed reverse transcription-PCR (RT-PCR) assays at the trial sites and with a seminested RT-PCR and an analyte-specific reagent (Cepheid) at a reference laboratory. The 5' nontranslated region was the target for all of the PCR assays except the seminested RT-PCR, which amplified a VP1 sequence. The VP1 amplicon was sequenced to identify the enterovirus types. Consensus reference laboratory RT-PCR results were used to classify cases of enteroviral meningitis. The GXEA detected all of the enterovirus serotypes and none of the other microorganisms tested except rhinovirus 16. The assay was unaffected by moderate amounts of blood or blood components. Thirty-six (35%) of the CSF samples tested had at least one positive PCR result. Eleven different enterovirus serotypes were identified in the positive samples. The GXEA had a sensitivity of 97.1% (95% confidence interval [CI], 84.7 to 99.9%) and a specificity of 100% (95% CI, 94.6 to 100%) for the diagnosis of enteroviral meningitis.


Asunto(s)
Infecciones por Enterovirus/diagnóstico , Infecciones por Enterovirus/virología , Enterovirus/clasificación , Enterovirus/aislamiento & purificación , Técnicas de Diagnóstico Molecular/métodos , Regiones no Traducidas 5'/genética , Sangre , Líquido Cefalorraquídeo/virología , Enterovirus/genética , Humanos , Meningitis/virología , ARN Viral/análisis , ARN Viral/genética , ARN Viral/aislamiento & purificación , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Rhinovirus/genética , Rhinovirus/aislamiento & purificación , Sensibilidad y Especificidad , Análisis de Secuencia de ADN , Proteínas Virales/genética
7.
J Sep Sci ; 27(4): 275-83, 2004 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15334914

RESUMEN

The growing importance of analyzing the human genome to detect hereditary and infectious diseases associated with specific DNA sequences has motivated us to develop automated devices to integrate sample preparation, real-time PCR, and microchannel electrophoresis (MCE). In this report, we present results from an optimized compact system capable of processing a raw sample of blood, extracting the DNA, and performing a multiplexed PCR reaction. Finally, an innovative electrophoretic separation was performed on the post-PCR products using a unique MCE system. The sample preparation system extracted and lysed white blood cells (WBC) from whole blood, producing DNA of sufficient quantity and quality for a polymerase chain reaction (PCR). Separation of multiple amplicons was achieved in a microfabricated channel 30 microm x 100 microm in cross section and 85 mm in length filled with a replaceable methyl cellulose matrix operated under denaturing conditions at 50 degrees C. By incorporating fluorescent-labeled primers in the PCR, the amplicons were identified by a two-color (multiplexed) fluorescence detection system. Two base-pair resolution of single-stranded DNA (PCR products) was achieved. We believe that this integrated system provides a unique solution for DNA analysis.


Asunto(s)
ADN/aislamiento & purificación , Genoma Humano , Automatización , Secuencia de Bases , ADN/sangre , ADN/genética , Cartilla de ADN , Electroforesis/instrumentación , Electroforesis/métodos , Diseño de Equipo , Humanos , Miniaturización/métodos , Reacción en Cadena de la Polimerasa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...